Reference designs

Whole designs to open, take apart and make your own.

Each reference design is a complete estate: racks with real device and rack types from the built-in catalogue, every port cabled, every power inlet on an A or B PDU, and Design review reporting no errors or warnings. Open one to see what a finished design looks like in Railyard, then rename it, change the hardware and grow it into your own. Each one is small enough to open in a moment and fits the Community plan's 25 racks per estate, so anyone can use every design.

Try one in your browser: the links below open the design in the browser-only editor, with no account. With an account, choose + New project, then Reference design, pick one and name the project. In the browser-only editor, Project settings → General → Open a reference design… opens the same gallery (it replaces the project saved in the browser, after you download a backup). The command palette's Open a reference design… goes to whichever applies.

Edge or branch rack

One 27U comms rack for a branch office: a firewall pair, two access switches, two servers, a patch panel and a UPS. 1 rack · 9 devices · 38 cables · 1.3 kW planned.

Rack elevation of the Edge or branch rack reference design
  • A small estate in one space (Office → Rack), the shape a branch or edge site takes
  • A firewall pair with its HA links and one leg to each switch
  • Structured cabling: 24 floor outlets on a patch panel, patched half to each switch
  • A feed through a UPS and a feed straight from mains, so either can fail

Check before you rely on it: Power is 230 V single phase. The UPS (feed A) and the horizontal PDU (feed B) each come from their own building circuit, which the design cannot check. Each server's planned draw is an estimate for a typical configuration (350 W), not the PSU rating. The panel's rear ports are the permanent links to the floor outlets, which are outside the rack and not drawn. The ISP handoff arrives on each firewall's ethernet1/1 and is not drawn.

Open Edge or branch rack in your browser

Enterprise server room

A head office server room: one row of three racks for the network, a virtualisation cluster and its storage. 3 racks · 25 devices · 51 cables · 6.5 kW planned.

Floor plan of the Enterprise server room reference design
  • A network rack with a core switch pair, a firewall pair, an out-of-band management switch and a console server
  • Eight hosts and a storage array, each dual-homed to both core switches
  • A separate management network for every iLO, switch and PDU network port
  • A/B 0U PDUs in every rack, each inlet on its own feed, from the room's A and B power panels
  • The room drawn on its floor plan, with its door and two rated cooling units

Check before you rely on it: Power is 230 V single phase at 32 A per PDU; the A and B PDUs are fed from separate distribution boards. Each host's 25GbE ports are on a two-port adapter fitted in the server (shown as module ports), cabled with passive DACs to the core in the next rack. Hosts' planned draws are estimates for a typical virtualisation configuration, not PSU ratings. The building's floor and riser links land on the network rack's patch panels and are not drawn. The two room coolers are rated 12 kW each, so either one carries the room's 6.5 kW.

Open Enterprise server room in your browser

Two-row colocation cage

A six-rack cage in a colocation hall: two rows on a contained cold aisle, carrier cross-connects, edge routers, a core pair and five compute racks. 6 racks · 74 devices · 192 cables · 31 kW planned.

Floor plan of the Two-row colocation cage reference design
  • A cage drawn on the hall's floor plan: two rows facing a contained cold aisle, the door and the provider's A and B power panels
  • Carrier cross-connects landing on a fibre panel, patched to a pair of edge routers
  • A core pair with every top-of-rack pair uplinked to both, across the aisle
  • Each rack's A and B PDUs fed from the provider's separate panels

Check before you rely on it: The provider supplies two 32 A single-phase feeds per rack, A from RPP-A and B from RPP-B; the panel ratings are what the contract allows for this cage. Cooling is the provider's: the two rated units stand for the hall's cooling serving this cage, which you should confirm against the contract. The cross-connect panel's rear ports are the carriers' circuits from the meet-me room, which are outside the cage and not drawn. Each host's 25GbE ports are on a two-port adapter fitted in the server (shown as module ports). Uplinks across the aisle are active optical cables. Hosts' planned draws (650 W) are estimates for a typical configuration, not PSU ratings.

Open Two-row colocation cage in your browser

Leaf-spine fabric pod

A five-rack fabric pod: two spines, four leaf pairs and forty dual-homed hosts, with the topology drawn from the cables. 5 racks · 65 devices · 168 cables · 19 kW planned.

Floor plan of the Leaf-spine fabric pod reference design
  • A two-tier Clos fabric: every leaf has one 100G uplink to each spine
  • Leaf pairs with peer links, and every host on both leaves of its rack
  • A topology diagram created from the cabling and laid out in tiers
  • Networks on the cables (fabric, production, management) for the topology filter and the exports
  • The hall drawn on its floor plan, with rated cooling and the A and B power panels feeding every PDU

Check before you rely on it: Each host's 25GbE ports are on a two-port adapter fitted in the server (shown as module ports). Leaf to spine links are passive QSFP28 DACs where the racks are close; the far leaf rack, beyond a DAC's 5 m, uses active optical cables. Hosts' planned draws (380 W) are estimates for a typical configuration, not PSU ratings. Power is 230 V single phase at 32 A per PDU, A from RPP-A and B from RPP-B. The two cooling units are rated 30 kW each, so either one carries the pod's 19 kW.

Open Leaf-spine fabric pod in your browser

GPU cluster pod

Sixteen 8-GPU servers in four 20 kW racks: a rail-optimised 400G back end, a front-end pair, three-phase PDUs and N+1 cooling. 5 racks · 34 devices · 131 cables · 80 kW planned.

Floor plan of the GPU cluster pod reference design
  • High-density racks: four 4U GPU servers per rack at about 20 kW, on 22 kW three-phase PDUs that each carry the rack alone, even at peak
  • A rail-optimised back end: adapter n of every server on rail switch n, four rails
  • A separate 100G front-end network for storage and access, and out-of-band management for every BMC, switch and PDU
  • A drawn hall with rated cooling, power panels and cold-aisle containment, with Design review checking the heat against the cooling with one unit out

Check before you rely on it: Each server holds eight double-width PCIe GPUs and is planned at 4,800 W, a typical full-load figure; check your configuration's. Every server has four 400G OSFP adapters (one per pair of GPUs) and a two-port 100G adapter, shown as module ports. Back-end and front-end links are active optical cables, since every server sits in another rack than its switches. Each rack takes two 32 A three-phase feeds (A from RPP-A, B from RPP-B). The servers' PSU connectors are not recorded in the catalogue, so the cords are not checked. One scalable unit of sixteen servers needs no spine: traffic between rails crosses inside each server. Growing past one unit adds a spine layer. The four cooling units are rated 40 kW each; any three carry the pod.

Open GPU cluster pod in your browser

How they are made

The designs are built by a script in Railyard's repository from the bundled device-type catalogue, through the editor's own commands (spaces, racks, cables, Auto-connect power), and rebuilt when the catalogue changes. A test holds every design to the same bar: it loads, uses only catalogue types, reviews with no errors, raises only the warnings its notes explain, and exports to every format and deliverable.

RailyardData-centre design, before the DCIM.

Who it's for

  • Data centre design for integrators and consultancies
  • Colocation cage and suite design for sales engineers
  • Data centre migration planning
  • Rack planning without Visio and Excel
  • NetBox Branching, Nautobot Design Builder or Railyard

Guides

  • Rack elevation planning
  • Structured cabling planning
  • Rack power planning
  • NetBox and Nautobot export
  • Data centre floor planning